Your Allen Bradley motor [type] will carefully evaluated by experienced technicians to determine if it is faulty. Encoders or resolvers are tested with a variety of diagnostic instruments. After disassembly and cleaning, windings are checked with a digital DC hi-pot and surge tester, and all critical mechanical dimensions are measured with micrometers. All test results become part of the permanent record of the motor in our database.
If the motor winding has failed, the old winding is carefully reverse engineered before being stripped with a mechanical stripping method that prevents any damage to the insulated core. A new winding utilizing class H magnet wire and all class H insulation is installed.
Worn mechanical components are fabricated or re-furbished by one of our expert machinists. Our machine shop is fully equipped with lathes, mills, and precision grinding equipment. Rotating components are precision balanced on one of our Schenck Trebel hard bearing balancing machines.